Experion Controller Overview

 

Honeywell offers multiple ExperionPKS controllers, ranging from embedded controller platforms with dedicated IO hardware

to PC based control environments for supervisory control tasks or simulation. They all support one or more different network

types to integrate the controllers with the ExperionPKS Server. They share a common Control Execution Environment (CEE)

software infrastructure and a common builder tool. Together with the different station types, they form the ExperionPKS

system. This specifications document provides details specifically related to the ExperionPKS C300 controller.

 

C300 Configuration Options

 

 

C300 Configuration Options
  50 ms CEE 20 ms CEE4
Control Networks Supported FTE only 1 FTE only 1
Supported C300 Models 6, 7 CC-PCNT01

CC-PCNT02
CC-PCNT01

CC-PCNT02
Device Index Configuration Between 1 and 510 Between 1 and 510
IOTA Size 6 inches 6 inches
Number of I/O Links Supported

I/O Link Speeds Available

375 Kbaud (PMIO Link)
750 Kbaud (Series C IO
Link)

  750 Kbaud (Series C IO
  Link)

   375 Kbaud (PMIO Link) is not
   supported
Base Execution Periods Supported 50 ms 20 ms (optional)4
Redundancy Supported Yes Yes

Remote – Non-Series C I/O Supported
Yes – PM I/O or Series A
I/O 3

No – Only Series C I/O
supported with limited
capacities.
I/O Module Execution Period 50 ms 20 ms
Configurable Values for CM/SCM/RCM Execution Periods 5 50, 100, 200, 500, 1000,
2000, 5000, 10000,
20000, 300000, 60000
ms.
20, 40, 80, 200, 400, 800
ms.

CMs Only – SCM/RCM/MR
not supported
Configurable Values of Peer Update Rates (period).
Defines the period at which data is updated for all ‘pull/get’
requests for peer data required by all blocks within a CEE.
100, 200, 500, 1000 ms. 100, 200, 500, 1000 ms.
C300 Time Source SNTP, PTPv2 SNTP, PTPv2
SNTP Update Period 1 minute 1 minute
GPS Time Support2 No No
PTP Update Period 30 seconds 30 seconds

Note 1 – Currently, every C300 must be connected to a Control Firewall
Note 2 – A GPS connector is available on the IOTA, but it is not supported until a future release.

Note 3 –C300 20ms supports only Series C I/O.

Note 4 – Requires separately loaded Firmware Version and License.  C300 20 ms CEE may ONLY be used for
                Honeywell Turbine Control Solution (TMCS) in R410.1.
Note 5- Slower execution periods are supported for Profit Controller Block only
Note 6- C300 controller CC-PCNT02 replaces CC-PCNT01 for new installations and field replacements.

Note 7-  C300 controller must use CC-PCNT02 model with extended functionality firmware image for C300 extended
                functionalities (EIM, Profit Controller)

 

More Honeywell Products for your choice:  

 

CC-GAIX11

CC-GAIX21

CC-GAOX11

CC-GAOX21

CC-GDIL11

CC-MCAR 51202335-300

CC-MCAR01

CC-MCARW1

CC-PAIH01

CC-PAIH02

CC-PAOH01

CC-PCF901

CC-PCNT01

CC-PCNT02

CC-PDIL01

CC-PDOB01

CC-SCMB02

CC-TAIN01

CC-TAIX01

CC-TAIX01 51308363-175

CC-TAIX11

CC-TAON11

CC-TAOX01

CC-TAOX01  51308351-175

CC-TAOX11 51308353-175

CC-TCF901

CC-TCNT01

CC-TDIL01

CC-TDOB01

CC-TDOB01 51308371-175

CC-TDOB11

CR-DINA-DO16-6A

CR-DINA-DO16-6A, discontinued, replaced by: RMD-16DO-L-1C-W-D24-FU-GK

CW4500 ,P/N 6560010024

Direct Station (CV-STAD01) - 4 pcs.

DSA SERVER ENABLER, PER CONNECTION (CV-XRESR1) - 1 pcs.

Experion Software Protection Dongle Enabler (EP-DONENB) - 1 pcs.

Experion USB Dongle (EP-DONUSB) - 2 pcs.

FC-IO-0001

FC-IO-0002,difficult to order,quoted model:FC-IOCHAS-0002R

FC-IOCHAS-0001R

FC-IOCHAS-0002R

FC-IOCHAS-0002S

FC-IOTA-R24

FC-MCAR-02

FC-PDB-0824P

FC-RUSLS-3224

FC-SAI-1620M

FC-SDI-1624

FC-SDO-0824

FC-SIC2020

FC-TSDI-1624

FC-USI-0002

FS24X-911-24-1

FS-FEEDER-24R

FS-IOBUS-CPIO4

FS-IOBUS-CPIO5

FS-PDC-ART05

FS-PDC-IOEP1A

FS-PDC-IOEP2A

FS-PDC-IOEP3A

FS-PDC-IOIP1A

FS-PDC-IOSET

FS-SICC-0001 L=5м

FS-TSAI-1620m

FS-TSDO-0824

FTA-C300-16AO-SH-S, 1222980000

FTA-MC

H-010-0901-000

H-10-103-04

H-10-120-10

M5-BAT08

MC- PDOY22 80363975-150

MC-PAIH03 51304754-150

MC-PAOY22 80363969-175

MC-PDIY22 80363972-150

MC-PDOY22

MC-TAIH03 51309136-175,replaced by: MC-TAIH02

MC-TAMR03 51309218-175

MC-TAOY22 80366481-175

MC-TDIY22 51204160-175

MC-TDOY22 80366183-175

MC-TLPA02 51309204-175

 

We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.

 

We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.

 

Contact:

HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat) 
Previous:Yokogawa AAV544-H53/K4A00 AAV544-S53/A4S10 DCS Module Arrive Next:Honeywell CC-GAIX11 Analog Input PKS Module Arrived
 Footer begin -->