Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmit
	Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	
	
	

	Overview of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or ?”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.
	Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors,downtime is also reduced and on-going costs are minimised through the use of poison resistant flammable sensors and patented Surecel toxic sensors.
	
Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	There are three different types of the XCD transmitter for use with three different families of sensors.
	The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL. Two IR Hydrocarbon sensors are available; one linearised to Methane and one linearised to Propane. The Propane version has linear cross sensitivities factors for Ethylene,Butane and Pentane. There is also an IR CO2 sensor available in the range 0-2%Vol.
	The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulphide,(H2S), Nitrogen Dioxide (NO2) and Hydrogen(H2). The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.
	A transmitter can auto-recognise any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.
	Sensepoint XCD-RTD transmitter (use with oxygen and toxic Sensepoint sensors) of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	Sensepoint XCD-RTD (Remote Toxic Detector) allows for a gas sensor from a wider selection of 2-wire 4 to 20mA input type Toxic and Oxygen sensors to be fitted directly to the transmitter housing, or wired remotely from another location.
	KIT includes Transmitter, Magnetic Wand and Allen Key
	Sensepoint XCD of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	Transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres – indoors and outdoors.
	Features & Benefits of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   All-in-one gas monitoring solution
	*   Proven SurecellTM electrochemical sensors
	*   Global approvals
	Quick Specs of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   Input voltage range: 16 to 32 VDC (24 VDC nominal)
	*   Communication: RS485, MODBUS RTU
	*   Certified temperature range: 40°to +149°F (-40°to +65°C)
	Product Overiew of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	 
	*   Sensepoint XCD now has remote monitoring capabilities for its toxic and Oxygen sensors. Its  remote capability is designed to offer excellent flexibility of use and is an ideal solution for hard-to-reach locations or areas where the transmitter needs to be separate from the sensor.
	Additional Features and Benefits of Honeywell SPXCDALMTX4 Sensepoint XCD Fixed Gas Detectors SPXCDALMTX4 Transmitter Arrived
	All-In-One Gas Monitoring Solution of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   Flammable (catalytic or infrared), toxic and oxygen versions available
	*   Serves new/retrofit, indoor/outdoor applications
	*   Stainless steel or aluminum explosion-proof housing options
	*   IP66 as standard
	Proven and Reliable Sensor Technology of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   SurecellTM electrochemical sensors
	*   Poison immune infrared sensors
	*   Poison resistant catalytic bead sensors
	*   Long life sensors
	Global Approvals of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   US and Latin America, European, Canadian and Asian
	*   Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
	Easy to Use of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   User friendly and intuitive tri-color backlit display with digits, bar graph and icons
	*   Fully configurable via magnetic switches
	*   Optional remote sensor mounting
	*   Selectable sink or source 4-20mA output
	*   MODBUS communications for remote diagnostics/configuration
	Cost Effective of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   Common transmitter platform
	*   Minimal training required
	*   Reduced spares
	*   Non-intrusive, one-man operation
	*   Plug-in sensor replacement
	*   MODBUS multi drop option offers cabling savings
	Simple Installation of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	*   Plug-in display module removes to give access to terminal area
	*   Integral mounting bracket
	*   2 x M20 or ?” NPT cable/conduit entries
	*   Removable plug/socket type terminal blocks for
	*   Sink/source switch to suit preferred wiring topology
	*   Integral mounting plate attaches to surface, horizontal or vertical piping
	ACCESSORIES of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	Sensepoint XCD Duct mounting kit
	SPXCDDMK
	Duct mounting kit
	Sensepoint XCD Mounting bracket
	SPXCDMTBR
	Mounting bracket (inc. bolts, nuts, brackets)
	Sensepoint XCD Sunshade / Deluge Protection
	SPXCDSDP
	Sunshade / Deluge Protection
	Ordering Codes of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDALMFX SPXCDALMRX SPXCDALMPX SPXCDALMO1 SPXCDALMHX SPXCDALMCX SPXCDALMG1 SPXCDALMNX SPXCDALMB1 SPXCDALMB2 SPXCDASMFX SPXCDASMRX SPXCDASMPX SPXCDASMO1 SPXCDASMHX SPXCDASMCX SPXCDASMG1 SPXCDASMNX SPXCDASMB1 SPXCDASMB2 SPXCDALMFXM SPXCDALMRXM    SPXCDALMPXM SPXCDALMO1M SPXCDALMHXM SPXCDALMCXM SPXCDALMG1M SPXCDALMNXM SPXCDALMB1M SPXCDALMB2M SPXCDASMFXM SPXCDASMRXM SPXCDASMPXM SPXCDASMO1M SPXCDASMHXM SPXCDASMCXM SPXCDASMG1M SPXCDASMNXM SPXCDASMB1M SPXCDASMB2M SPXCDULNFX SPXCDULNRX SPXCDULNPX SPXCDULNO1 SPXCDULNHX SPXCDULNCX SPXCDULNG1 SPXCDULNNX SPXCDULNB1 SPXCDULNB2 SPXCDUSNFX SPXCDUSNRX SPXCDUSNPX SPXCDUSNO1 SPXCDUSNHX SPXCDUSNCX SPXCDUSNG1 SPXCDUSNNX SPXCDUSNB1 SPXCDUSNB2 SPXCDULNFXM SPXCDULNRXM SPXCDULNPXM SPXCDULNO1M SPXCDULNHXM SPXCDULNCXM SPXCDULNG1M SPXCDULNNXM SPXCDULNB1M SPXCDULNB2M SPXCDUSNFXM SPXCDUSNRXM SPXCDUSNPXM SPXCDUSNO1M SPXCDUSNHXM SPXCDUSNCXM SPXCDUSNG1M SPXCDUSNNXM SPXCDUSNB1M SPXCDUSNB2M SPXCDALMTX4 SPXCDASMTX4 SPXCDULNTX4 SPXCDUSNTX4 SPXCDALMTX4M SPXCDASMTX4M SPXCDULNTX4M SPXCDUSNTX4M SPXCDALMRFD SPXCDASMRFD SPXCDULNRFD SPXCDUSNRFD SPXCDALMRFDM SPXCDASMRFDM SPXCDULNRFDM SPXCDUSNRFDM SPXCDXSRFXSS SPXCDXSRRXSS SPXCDXSRPXSS SPXCDXSRB1SS SPXCDXSRB2SS 
	Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMTX4 SPXCDALMTX4 SPXCDUSNTX4 SPXCDULNTX4 SPXCDASMTX4M SPXCDALMTX4M SPXCDUSNTX4M SPXCDULNTX4M SPXCDMTBR SPXCDSDP SPXCDDM4 SPXCDDM4M SPXCDTM4 SPXCDAKS SPXCDHWES SPXCDEBS 2106B1100 2106B1316 2106B1300 2106B1301 2106B1302 2106B1305 2106B1306 2106B1307 2106B1310 2106B1311 2106B1313 2106B1314 2106B1110 2106B2114 2106D2055 02000-A-1635 02000-A-1640 02000-A-1642 02000-A-1645 2106B1130 2106B1545 2106B1549 2106B1548 2106B1547 2106B1595 2106B1596 2110B1829 2110B2822 2110B3250 2110B2820 2110B2829 2110B2073 2110B1822 2110B0395 2110B0398 2110B2150 2110B3072 2110B3000 2110B3010 2110B3020 2110B3040 2110B3090 2110B3100 2110B3110 2110B3130 2110B3140 2110B3150 2110B3160 2110B3052 2110B3430 2110B3200 2110B3210 2110B3220 2110B3230 2110B3240 2110B3250 2110B3530 2110B3270 2110B3290 2110B3300 2110B3320 2110B3330 2110B3340 2110B3350 2110B3570 2110B3540 2110B3550 2110B3560 2110B3360 2110B3370 2110B3380 2110B3390
	Part Numbers of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	Instrument - ATEX/IECEx/CHINA Approval (316SS)  Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMFX ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
	SPXCDASMRX ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
	SPXCDASMPX ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry
	SPXCDASMO1 ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with 316SS, M20 Entry
	SPXCDASMNX ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, M20 Entry
	SPXCDASMHX ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry
	SPXCDASMCX ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry
	SPXCDASMG1 ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with 316SS, M20 Entry
	SPXCDASMB1 ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, M20 Entry
	Instrument - ATEX/IECEx/CHINA Approval (LM25) Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDALMFX ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
	SPXCDALMRX ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
	SPXCDALMPX ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry
	SPXCDALMO1 ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with LM25, M20 Entry
	SPXCDALMNX ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, M20 Entry
	SPXCDALMHX ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry
	SPXCDALMCX ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry
	SPXCDALMG1 ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with LM25, M20 Entry
	SPXCDALMB1 ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, M20 Entry
	Instrument - UL/CSA Approval (316SS) Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDUSNFX UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry
	SPXCDUSNRX UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry
	SPXCDUSNPX UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry
	SPXCDUSNO1 UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4"NPT Entry
	SPXCDUSNHX UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4"NPT Entry
	SPXCDUSNCX UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4"NPT Entry
	SPXCDUSNNX UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4"NPT Entry
	SPXCDUSNG1 UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4"NPT Entry
	SPXCDUSNB1 UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4"NPT Entry
	Instrument - UL/CSA Approval (LM25) Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDULNFX UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
	SPXCDULNRX UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
	SPXCDULNPX UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry
	SPXCDULNO1 UL/CSA approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4"NPT Entry
	SPXCDULNHX UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4"NPT Entry
	SPXCDULNCX UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4"NPT Entry
	SPXCDULNNX UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, 3/4"NPT Entry
	SPXCDULNG1 UL/CSA approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4"NPT Entry
	SPXCDULNB1 UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, 3/4"NPT Entry
	Instrument - ATEX/IECEx/CHINA Approval (316SS) with ModBus    Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMFXM ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
	SPXCDASMRXM ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
	SPXCDASMPXM ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, M20 Entry, with ModBus
	SPXCDASMO1M ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with 316SS, M20 Entry, with ModBus
	SPXCDASMNXM ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, M20 Entry, with ModBus
	SPXCDASMHXM ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, M20 Entry, with ModBus
	SPXCDASMCXM ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, M20 Entry, with ModBus
	SPXCDASMG1M ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with 316SS, M20 Entry
	SPXCDASMB1M ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, M20 Entry, with ModBus
	Instrument - ATEX/IECEx/CHINA Approval (LM25) with ModBus    Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDALMFXM ATEX/IECEx and AP approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
	SPXCDALMRXM ATEX/IECEx and AP approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
	SPXCDALMPXM ATEX/IECEx and AP approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, M20 Entry, with ModBus
	SPXCDALMO1M ATEX/IECEx and AP approved SP XCD Oxygen 25.0%/Vol with LM25, M20 Entry, with ModBus
	SPXCDALMNXM ATEX/IECEx and AP approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, M20 Entry, with ModBus
	SPXCDALMHXM ATEX/IECEx and AP approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, M20 Entry, with ModBus
	SPXCDALMCXM ATEX/IECEx and AP approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, M20 Entry, with ModBus
	SPXCDALMG1M ATEX/IECEx and AP approved SP XCD Hydrogen 0-1000ppm with LM25, M20 Entry, with ModBus
	SPXCDALMB1M ATEX/IECEx and AP approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, M20 Entry, with ModBus
	Instrument - UL/CSA Approval (316SS) with ModBus  Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDUSNFXM UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNPXM UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNO1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4"NPT Entry, with ModBus
	SPXCDUSNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4"NPT Entry, with ModBus
	Instrument - UL/CSA Approval (LM25) with ModBus   Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDULNFXM UL/CSA approved SP XCD Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNPXM UL/CSA approved SP XCD Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNO1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4"NPT Entry, with ModBus
	SPXCDULNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with LM25, 3/4"NPT Entry with ModBus
	Accessories of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	S3KCAL Calibration cup
	SPXCDCC Collecting cone for use with lighter than air gases
	SPXCDDMK Duct mounting kit
	SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
	SPXCDSDP Sunshade / Deluge Protection
	00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved
	Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	 
	SPXCDALMFX SPXCDALMRX SPXCDALMPX SPXCDALMO1 SPXCDALMHX  SPXCDALMCX  SPXCDALMG1 SPXCDALMNX SPXCDALMB1 SPXCDALMB2 SPXCDASMFX SPXCDASMRX SPXCDASMPX SPXCDASMO1 SPXCDASMHX SPXCDASMCX SPXCDASMG1 SPXCDASMNX SPXCDASMB1 SPXCDASMB2 SPXCDALMFXM SPXCDALMRXM SPXCDALMPXM SPXCDALMO1M SPXCDALMHXM SPXCDALMCXM SPXCDALMG1M SPXCDALMNXM SPXCDALMB1M SPXCDALMB2M SPXCDASMFXM SPXCDASMRXM SPXCDASMPXM SPXCDASMO1M SPXCDASMHXM SPXCDASMCXM SPXCDASMG1M SPXCDASMNXM SPXCDASMB1M SPXCDASMB2M SPXCDULNFX SPXCDULNRX SPXCDULNPX SPXCDULNO1 SPXCDULNHX SPXCDULNCX SPXCDULNG1 SPXCDULNNX SPXCDULNB1 SPXCDULNB2  SPXCDUSNFX SPXCDUSNRX SPXCDUSNPX SPXCDUSNO1 SPXCDUSNHX SPXCDUSNCX SPXCDUSNG1 SPXCDUSNNX SPXCDUSNB1 SPXCDUSNB2 SPXCDULNFXM SPXCDULNRXM SPXCDULNPXM SPXCDULNO1M SPXCDULNHXM SPXCDULNCXM SPXCDULNG1M SPXCDULNNXM SPXCDULNB1M SPXCDULNB2M SPXCDUSNFXM SPXCDUSNRXM SPXCDUSNPXM SPXCDUSNO1M SPXCDUSNHXM SPXCDUSNCXM SPXCDUSNG1M SPXCDUSNNXM SPXCDUSNB1M SPXCDUSNB2M SPXCDALMTX4 SPXCDASMTX4 SPXCDULNTX4 SPXCDUSNTX4 SPXCDALMTX4M SPXCDASMTX4M SPXCDULNTX4M SPXCDUSNTX4M SPXCDALMRFD SPXCDASMRFD SPXCDULNRFD SPXCDUSNRFD SPXCDALMRFDM SPXCDASMRFDM SPXCDULNRFDM SPXCDUSNRFDM SPXCDXSRFXSS SPXCDXSRRXSS SPXCDXSRPXSS SPXCDXSRB1SS SPXCDXSRB2SS    
	Sensepoint XCD Sensors (316 Stainless Steel) of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDXSFXSS Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
	SPXCDXSRXSS Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
	SPXCDXSO1SS Oxygen 25.0%/Vol only
	SPXCDXSHXSS Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm)
	SPXCDXSCXSS Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm)
	SPXCDXSNXSS Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm)
	SPXCDXSG1SS Hydrogen 0-1000ppm only
	SPXCDXSPXSS Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
	SPXCDXSB1SS Carbon Dioxide IR 0-2.00%VOL only
	Sensepoint XCD Transmitter (without Sensor)
	Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDALMTXO ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, LM25 with M20 Entry
	SPXCDALMTXT ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, LM25 with M20 Entry
	SPXCDALMTXF ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, LM25 with M20 Entry
	SPXCDASMTXO ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, 316SS with M20 Entry
	SPXCDASMTXT ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, 316SS with M20 Entry
	SPXCDASMTXF ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, 316SS with M20 Entry
	SPXCDALMTXOM ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, LM25 with M20 Entry and ModBus
	SPXCDALMTXTM ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter with LM25, M20 Entry, with ModBus
	SPXCDALMTXFM ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, LM25 with M20 Entry and ModBus
	SPXCDASMTXOM ATEX/IECEx/China approved Sensepoint XCD O2 Transmitter, 316SS with M20 Entry and ModBus
	SPXCDASMTXTM ATEX/IECEx/China approved Sensepoint XCD Toxic Transmitter, 316SS with M20 Entry and ModBus
	SPXCDASMTXFM ATEX/IECEx/China approved Sensepoint XCD IR and FLAM Transmitter, 316SS with M20 Entry and ModBus
	SPXCDULNTXO UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4"NPT Entry
	SPXCDULNTXT UL approved Sensepoint XCD Toxic Transmitter, LM25 with 3/4"NPT Entry
	SPXCDULNTXF UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4"NPT Entry
	SPXCDUSNTXO UL approved Sensepoint XCD O2 Transmitter, 316SS with 3/4"NPT Entry
	SPXCDUSNTXT UL approved Sensepoint XCD Toxic Transmitter with 316SS, 3/4"NPT Entry
	SPXCDUSNTXF UL approved Sensepoint XCD IR and FLAM Transmitter, 316SS with 3/4"NPT Entry
	SPXCDULNTXOM UL approved Sensepoint XCD O2 Transmitter, LM25 with 3/4"NPT Entry and ModBus
	SPXCDULNTXTM UL approved Sensepoint XCD Toxic Transmitter, LM25 with 3/4"NPT Entry and ModBus
	SPXCDULNTXFM UL approved Sensepoint XCD IR and FLAM Transmitter, LM25 with 3/4"NPT Entry and ModBus
	SPXCDUSNTXOM UL approved Sensepoint XCD O2 Transmitter, 316SS with 3/4"NPT Entry and ModBus
	SPXCDUSNTXTM UL approved Sensepoint XCD Toxic Transmitter, 316SS with 3/4"NPT Entry and ModBus
	SPXCDUSNTXFM UL approved Sensepoint XCD IR and FLAM Transmitter, 316SS with 3/4"NPT Entry and ModBus
	Miscellaneous Spares of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDDMF Replacement display module for Cat and IR
	SPXCDDMT Replacement display module for O2 and Toxic
	SPXCDDMFM Replacement display module (Cat and IR) with ModBus
	SPXCDDMTM Replacement display module O2 and Toxic with ModBus
	SPXCDTMF Replacement terminal module for Cat and IR
	SPXCDTMO Replacement terminal module for O2
	SPXCDTMT Replacement terminal module for Toxic
	SPXCDMAG Magnet
	SPXCDWP XCD Weather proof cap
	SPXCDSRLS Sensor Retainer with locking screw
	SPXCDAKS Allen key for stopper
	SPXCDHWES Hex wrench for earth screw
	SPXCDEBS Earth Bracket and screws
	Instrument - Sensepoint XCD RFD Transmitter of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMRFD ATEX/IECEx and AP approved SP XCD RFD Transmitter with 316SS
	SPXCDALMRFD ATEX/IECEx and AP approved SP XCD RFD Transmitter with LM25
	SPXCDUSNRFD cCSAus approved SP XCD RFD Transmitter with 316SS, 3/4"NPT Entries
	SPXCDULNRFD cCSAus approved SP XCD RFD Transmitter with LM25, 3/4" NPT Entries
	Instrument - Sensepoint XCD RFD Remote Plug-in Sensor and Socket   Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	 
	SPXCDXSRFXSS Sensepoint XCD RFD remote plug-in sensor and socket, flammable CAT 0-100%LEL (20,0 to 100.0%LEL)
	SPXCDXSRRXSS Sensepoint XCD RFD remote plug-in sensor and socket, Methane IR 0-100%LEL (20,0 to 100.0%LEL)
	SPXCDXSRPXSS Sensepoint XCD RFD remote plug-in sensor and socket, Propane IR 0-100%LEL (20,0 to 100.0%LEL)
	SPXCDXSRB1SS Sensepoint XCD RFD remote plug-in sensor and socket, Carbon Dioxide IR 0-2.00%VOL only
	Instrument - Sensepoint XCD RFD Transmitter with ModBus   Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMRFDM ATEX/IECEx and AP approved SP XCD RFD Transmitter, 316SS, 2x M20 and 1x M25 entries, with ModBus
	SPXCDALMRFDM ATEX/IECEx and AP approved SP XCD RFD Transmitter, LM25, 2x M20 and 1x M25 entries, with ModBus
	SPXCDUSNRFDM cCSAus approved SP XCD RFD Transmitter with 316SS, 3/4"NPT Entries, with ModBus
	SPXCDULNRFDM cCSAus approved SP XCD RFD Transmitter with LM25, 3/4" NPT Entries, with ModBus
	Accessories of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDWP XCD Weather proof cap
	S3KCAL Calibration cup (flow adapter) for Series 3000 and XNX EC toxic sensors
	SPXCDCC Collecting cone for use with lighter than air gases
	SPXCDDMK Duct mounting kit
	SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
	SPXCDSDP Sunshade / Deluge Protection
	00780-A-0100 Honeywell Junction Box- Bartec OTB122 With Continuity Plate 1 X 25mm - 3 X 20mm Entries - ATEX Approved
	Spares of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDXSFXSS Flammable CAT 0-100%LEL (20 to 100%LEL, 10%LEL)
	SPXCDXSRXSS Methane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
	SPXCDXSPXSS Propane IR 0-100%LEL (20 to 100%LEL, 10%LEL)
	SPXCDXSB1SS Carbon Dioxide IR 0-2.00%VOL only
	SPXCDDMR XCD RFD Flam and IR Display Module
	SPXCDDMRM XCD RFD Flam and IR Display Module, ModBus
	SPXCDTMR XCD RFD Replacement Terminal Module
	SPXCDMAG Magnet
	SPXCDSRLS Sensor Retainer with locking screw
	SPXCDAKS Allen key for stopper
	SPXCDHWES Hex wrench for earth screw
	SPXCDEBS Earth Bracket and Screws
	Instrument - Sensepoint XCD RTD 4-20mA Input Transmitter (Transmitter Only)   Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMTX4 ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with 316SS, M20 Entry
	SPXCDALMTX4 ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with LM25, M20 Entry
	SPXCDUSNTX4 cCSAus approved SP XCD RTD Transmitter with 316SS
	SPXCDULNTX4 cCSAus approved SP XCD RTD Transmitter with LM25
	Instrument - Sensepoint XCD RTD 4-20mA Input Transmitter with ModBus (Transmitter Only)   Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDASMTX4M ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with 316SS, with ModBus
	SPXCDALMTX4M ATEX/IECEx and AP approved SP XCD 4~20mA Input Transmitter with LM25, with ModBus
	SPXCDUSNTX4M cCSAus approved SP XCD RTD Transmitter with 316SS, with ModBus
	SPXCDULNTX4M cCSAus approved SP XCD RTD Transmitter with LM25, with ModBus
	Accessories and Spares of Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
	SPXCDMTBR Mounting bracket (inc. bolts, nuts, brackets)
	SPXCDSDP Sunshade / Deluge Protection
	SPXCDDM4 Sensepoint XCD RTD Toxic and O2 Display Module
	SPXCDDM4M Sensepoint XCD RTD Toxic and O2 ModBus Display Module
	SPXCDTM4 Sensepoint XCD RTD Replacement terminal module
	SPXCDAKS Allen key for stopper
	SPXCDHWES Hex wrench for earth screw
	SPXCDEBS Earth Bracket and Screws
	SPXCDMAG Magnet
Honeywell SPXCDALMG1 Sensepoint XCD Explosion-Proof Transmitters SPXCDALMG1 Industrial Gas Detectors Arrived
		We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers,Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
	
		We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
	
		Contact:
	
		HONGKONG XIEYUAN TECH CO., LIMITED
	
		Email:becky@hkxytech.com   Web:www.hkxytech.com
	
		Mobile:+86-15972186287(Whatsapp & Wechat)
 
			 
		