Flush pressure sensor PM1608 PM-,25BREA01-E-ZVG/US

Robust stainless steel housing for use in the food and beverage industry

Hygienic, flush design

Resistant to high-pressure cleaning with aggressive cleaning agents

High temperature resistance and high protection rating

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analog outputs: 1

Measuring range

-0.0125...0.25 bar-12.5...250 mbar-0.182...3.626 psi-1.25...25 kPa

Process connectionthreaded connection G 1 external thread sealing cone

Application

Systemgold-plated contacts

Measuring elementceramic-capacitive pressure measuring cell

Temperature monitoringno

Applicationflush mountable for the food and beverage industry

Mediaviscous media and liquids with suspended particles; liquids and gases

Medium temperature[°C]-25...150

Min. bursting pressure

30000 mbar435 psi3000 kPa

Pressure rating

6000 mbar84 psi600 kPa

Vacuum resistance

-1000 mbar-0.1 MPa

Type of pressurerelative pressure

No dead spaceyes

MAWP (for applications according to CRN)[bar]10

Electrical data

Operating voltage[V]18...30 DC

Min. insulation resistance[MΩ]100; (500 V DC)

Protection classIII

Reverse polarity protectionyes

Measuring principlehydrostatic

Integrated watchdogyes

2-wire

Current consumption[mA]3.5...21.5

Power-on delay time[s]1

3-wire

Current consumption[mA]< 45

Power-on delay time[s]0.5

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analog outputs: 1

Outputs

Total number of outputs2

Output signalanalog signal; IO-Link; (configurable)

Number of digital outputs1; (IO-Link)

Number of analog outputs1

Analog current output[mA]4...20; (scalable)

Max. load[Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)

Short-circuit proofyes

Overload protectionyes

Measuring/setting range

Measuring range

-0.0125...0.25 bar-12.5...250 mbar-0.182...3.626 psi-1.25...25 kPa

Analog start point

-12.5...200 mbar-0.182...2.9 psi-1.25...20 kPa

Analog end point

37.5...250 mbar0.544...3.626 psi3.75...25 kPa

In steps of

0.1 mbar0.002 psi0.01 kPa

Factory setting

ASP = 0.0 barAEP = 250 mbar

Accuracy / deviations

Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)

Characteristics deviation[% of the span]< ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)

Linearity deviation[% of the span]< ± 0,15; (Turn down 1:1)

Hysteresis deviation[% of the span]< ± 0,15; (Turn down 1:1)

Long-term stability[% of the span]< ± 0,1; (Turn down 1:1; per year)

Total deviation over temperature range

Temperature rangetotal deviation

-25...15 °CCharacteristics deviation ± 0,1 % of the span / 10 K

15...80 °CCharacteristics deviation

80...150 °CCharacteristics deviation ± 0,15 % of the span / 10 K

Notes on the accuracy / deviationfor further details see section Diagrams and graphs

Reaction times

Damping for the analog output dAA[s]0...4

2-wire

Step response time analog output[ms]30

3-wire

Step response time analog output[ms]7

Interfaces

Communication interfaceIO-Link

Transmission typeCOM2 (38,4 kBaud)

IO-Link revision1.1

SDCI standardIEC 61131-9

ProfilesDigital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)

SIO modeno

Required master port classA

Process data analog3

Min. process cycle time[ms]3.2

IO-Link resolution pressure[mbar]0.05

IO-Link process data (cyclical)

Functionbit length

pressure16

device status4

IO-Link functions (acyclical)application specific tag; internal temperature

Supported DeviceIDs

Type of operationDeviceID

default669

Operating conditions

Ambient temperature[°C]-25...80

Storage temperature[°C]-40...100

ProtectionIP 67; IP 68; IP 69K

Tests / approvals

EMC

DIN EN 61000-6-2

DIN EN 61000-6-3

Shock resistance

DIN EN 60068-2-2750 g (11 ms)

Vibration resistance

DIN EN 60068-2-620 g (10...2000 Hz)

MTTF[years]323

Note on approval

Factory certificate available as download at www.factory-certificate.ifm

UL approval

UL approval numberJ022

Mechanical data

Weight[g]304.8

Housingtubular

Dimensions[mm]Ø 30.2 / L = 122

Materialstainless steel (1.4404 / 316L); PBT

Materials (wetted parts)ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE

Min. pressure cycles100 million

Tightening torque[Nm]20

Process connectionthreaded connection G 1 external thread sealing cone

Remarks

Pack quantity1 pcs.

Electrical connection

ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated

 

 

 

 

More Models:

 

EVC810 IIR200 PK5524 EVC005 II0011 EVC004 SI5002 IGT205 O1D100 PQ3834IFS204TA2105IFM216EVF566II5930II5697EVC002IG5596SI5010II5687KF5015VTV122SA5000E21248 PN3094SI6700E30448OY039SEY3099E11855G1501SE11252PM1608AL1930EVC146EVT006LI5131PT5404PN7299PN7209AC1254AC1258SI6800EC2082AL1102UGT524EVC086EVC003 OGH500II5689AC5222AC5218AC5233SU7000PN3093PN2160IM5115SH0500LR2050MVQ101IFC248IFC234IFC220IN5225IFT203O5E700IG6086E12339IGC222EVC714IGW201IF5888 EVC597IM5126IGT220IG5505IG5401EVS023EVC812VTV121IIS204IM0011SM9000IGT213IFT205PN2093PN2094E20005OGE101OGS100PM1506E33403

 


We mainly supply Siemens, Schneider, Honeywell, ABB, Allen Bradley, Mitsubishi, Omron, Eaton, Pepperl+Fuchs, MTL, Phoenix Contact,Weidmuller, Festo, IFM, Wago, Pilz, Degson, Sick, SMC, Norgren, Yokogawa, Yaskawa, Fluke, SEW, Emerson,Endress+Hauser,Vega, Hirschmann,Moxa, CISCO, Turck, Beckhoff, B&R, Balluff, Bifold, GE,Rittal, Proface, Wintek,Danfoss,EBM, YTC,Hach,Delta, Finder,Wohner, CHINT, Autonics,Testo, Bently Nevada, PR Electronics, Meanwell, Dell and so on .

 

 

We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.

 

 

Contact:

HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)

 

 

 

 

Previous:IFM AL1930 IO-Link Master with EtherCAT Interface Original A Next:IFM AC1254 AS-Interface Power Supply PSU-1AC/ASi-4A Arrived
 Footer begin -->