Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			
			
			
			
			 
		
Features of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
Switch Amplifier KFA6-SR2-Ex1.W.LB
			1-channel isolated barrier
		
			230 V AC supply
		
			Dry contact or NAMUR inputs
		
			Relay contact output
		
			Fault relay contact output
		
			Line fault detection (LFD)
		
			Reversible mode of operation
		
			Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			Technical data of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			General specifications of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Signal type Digital Input
		
			Functional safety related parameters of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Safety Integrity Level (SIL) SIL 2
		
			Supply of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Connection terminals 14, 15
		
			Rated voltage 207 ... 253 V AC, 45 ... 65 Hz
		
			Power dissipation 1.2 W
		
			Power consumption max. 1.3 W
		
			Input of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Connection side field side
		
			Connection terminals 1+, 2+, 3-
		
			Rated values acc. to EN 60947-5-6 (NAMUR)
		
			Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
		
			Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
		
			Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA
		
			Pulse/Pause ratio min. 20 ms / min. 20 ms
		
			Output of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Connection side control side
		
			Connection output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
		
			Output I signal ; relay
		
			Output II signal or error message ; relay
		
			Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
		
			Energized/De-energized delay approx. 20 ms / approx. 20 ms
		
			Mechanical life 107 switching cycles
		
			Transfer characteristics of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Switching frequency ≤ 10 Hz
		
			Galvanic isolation of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
		
			Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
		
			Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
		
			Output/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
		
			Indicators/settings of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Display elements LEDs
		
			Labeling space for labeling at the front
		
			Directive conformity of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Electromagnetic compatibility 
		
			Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
		
			Low voltage 
		
			Directive 2014/35/EU EN 61010-1:2010
		
			Conformity of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Electromagnetic compatibility NE 21:2006
		
			Degree of protection IEC 60529:2001
		
			Input EN 60947-5-6:2000
		
			Ambient conditions of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
		
			Mechanical specifications of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Degree of protection IP20
		
			Connection screw terminals
		
			Mass approx. 150 g
		
			Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
		
			Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
		
			Data for application in connection with hazardous areas of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			EU-Type Examination Certificate PTB 00 ATEX 2081
		
			Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
		
			Ex-Hexagon II (1)D [Ex ia Da] IIIC
		
			Ex-Hexagon I (M1) [Ex ia Ma] I
		
			Input Ex ia
		
			Voltage 10.6 V
		
			Current 19.1 mA
		
			Power 51 mW (linear characteristic)
		
			Supply 
		
			Maximum safe voltage 253 V AC (Attention! Um is no rated voltage.)
		
			Output 
		
			Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
		
			Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)
		
			Galvanic isolation 
		
			Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
		
			Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
		
			Directive conformity 
		
			Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012
		
			International approvals of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			FM approval 
		
			Control drawing 116-0035
		
			UL approval 
		
			Control drawing 116-0145
		
			CSA approval 
		
			Control drawing 116-0047
		
			IECEx approval IECEx PTB 11.0031
		
			Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
		
			General information of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
		
			Classifications of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			System Classcode
		
			ECLASS 11.0 27210121
		
			ECLASS 10.0.1 27210121
		
			ECLASS 9.0 27210121
		
			ECLASS 8.0 27210121
		
			ECLASS 5.1 27210121
		
			ETIM 8.0 EC001485
		
			ETIM 7.0 EC001485
		
			ETIM 6.0 EC001485
		
			ETIM 5.0 EC001485
		
			UNSPSC 12.1 32101514
	
			Similar models of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			HiC2821
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			HiC2822
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			KFA6-DU-Ex1.D
		
			Switch Amplifier, Timer Relay
		
			1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
		
			KFA6-SOT2-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFA6-SR-2.3L
		
			Switch Amplifier
		
			2-channel signal conditioner, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			KFA6-SR-2.3L.FA
		
			Switch Amplifier
		
			2-channel, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC 61508
		
			KFA6-SR2-Ex1.W
		
			Switch Amplifier
		
			1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA6-SR2-Ex1.W.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA6-SR2-Ex2.W
		
			Switch Amplifier
		
			2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA6-SR2-Ex2.W.IR
		
			Switch Amplifier
		
			2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			 
		
			KFD2-SH-Ex1
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
		
			KFD2-SOT3-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT3-Ex1.LB.IO
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT3-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT3-Ex2.IO
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
			KFD2-SR2-Ex1.W
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-SR2-Ex1.W.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-SR2-Ex2.W
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-SR3-2.2S
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-SR3-Ex2.2S
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KFD2-SRA-Ex4
		
			Switch Amplifier
		
			4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation
		
			KFD2-ST3-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			KFD2-ST3-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFU8-SR-1.3L.V
		
			Switch Amplifier, Timer Relay
		
			1-channel signal conditioner, Universal usage at different power supplies, 3-wire PNP/NPN sensor or push-pull input, 2 relay contact outputs, Adjustable energized/de-energized delay
		
			KHA6-SH-Ex1
		
			Switch Amplifier
		
			1-channel isolated barrier, 115/230 V AC supply, Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
		
			HiD2824
		
			Switch Amplifier
		
			4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			HiD2844
		
			Switch Amplifier
		
			4-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 4 passive transistor outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
		
			KCD2-SR-1.LB
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SR-2
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SR-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KCD2-SR-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			HiC2831
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2831R1
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2831R2
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2832R1
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2841
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2842
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2853
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
		
			HiC2853R1
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
		
			KCD2-SON-Ex1
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KCD2-SOT-1.LB
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-Ex2.SP
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KFA5-SR2-Ex1.W
		
			Switch Amplifier
		
			1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA5-SR2-Ex1.W.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA5-SR2-Ex2.W
		
			Switch Amplifier
		
			2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-DU-Ex1.D
		
			Switch Amplifier, Timer Relay
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KFD2-SH-Ex1.T.OP
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
		
			S1SD-1DI-1R
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors or AC/DC voltage sources, Relay contact output, Timer function, Configurable by DIP switches, Connection via screw terminals
		
			WE 77/Ex-1 115V
		
			Switch Amplifier
		
			1-channel, Control circuit EEx ia IIC, 115 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact)
		
			WE 77/Ex-1 230V
		
			Switch Amplifier
		
			1-channel, Control circuit EEx ia IIC, 230 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact)
		
			WE 77/Ex-2 115V
		
			Switch Amplifier
		
			2-channel, Control circuit EEx ia IIC, 115 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact) per channel
		
			WE 77/Ex-2 230V
		
			Switch Amplifier
		
			2-channel, Control circuit EEx ia IIC, 230 V AC supply voltage, Reversible mode of operation, Lead breakage (LB) monitoring, 1 relay contact output (change-over contact) per channel
		
			HiC2831R3
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2832
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2832R2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), SIL 2 (SC 3) acc. to IEC/EN 61508
		
			HiC2832R3
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			HiC2851
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Passive transistor output (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
		
			HiC2853R2
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (bus powered), Input for approved dry contacts or SN/S1N sensors, Application-specific outputs, Active voltage output, Passive transistor output (resistive), Line fault transparency (LFT), Up to SIL 3 acc. to IEC 61508
		
			KCD2-SON-Ex1.R1
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Usable as signal splitter (1 input and 2 outputs), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex1.R2
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex1.R3
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex1.SP
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex2.R1
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive), Application-specific outputs, Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex2.R2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SON-Ex2.R3
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Application-specific outputs, 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KCD2-SON-Ex2.SP
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-1.LB.SP
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-2
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-2.SP
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SOT-Ex1.LB.SP
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-1.LB
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-1.LB.SP
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-2
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-2.SP
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-ST-Ex1.LB.SP
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KCD2-ST-Ex2.SP
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KFA4-SR2-Ex2.W
		
			Switch Amplifier
		
			2-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact) per channel, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA5-DU-Ex1.D
		
			Switch Amplifier, Timer Relay
		
			1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD)
		
			KFA5-SOT2-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFA5-SR2-Ex2.W.IR
		
			Switch Amplifier
		
			2-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Latching relay contact output, Line fault detection (LFD)
		
			KFD2-SOT3-Ex2.IO-Y1
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFA4-SR2-Ex1.W
		
			Switch Amplifier
		
			1-channel, Control circuit EEx ia IIC, Reversible mode of operation, 1 relay contact output (change-over contact), EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFA4-SR2-Ex1.W.LB
		
			Switch Amplifier
		
			1-channel, Control circuit EEx ia IIC, Reversible mode of operation, Output I: relay contact output (change-over contact), Output II: optionally signal output/fault signal, EMC acc. to NAMUR NE 21, LB/SC monitoring, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-SR2-2.2S
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
		
			KFD2-SR2-Ex2.2S
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		
			KFD2-SOT2-Ex2.IO-Y181008
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, TTL level, Line fault detection (LFD), Reversible mode of operation
		
			KCD2-SR-Ex1.LB.SP
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SR-Ex2.SP
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT2-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT2-Ex1.LB.IO
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT2-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-SOT2-Ex2.IO
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-ST2-Ex1.LB
		
			Switch Amplifier
		
			1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Active fault output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KFD2-ST2-Ex2
		
			Switch Amplifier
		
			2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SR-1.LB.SP
		
			Switch Amplifier
		
			1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
		
			KCD2-SR-2.SP
		
			Switch Amplifier
		
			2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508
			
			 
	
		Ordering Codes of Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		 
	
		KFA6-SR2-Ex1.W.LB KFA6-SR2-Ex2.W.IR KFD2-DU-Ex1.D KFD2-ER-Ex1.W.LB KFD2-SH-Ex1.T KFD2-SH-Ex1.T.OP KFD2-SOT2-Ex1.N 
	
		KFD2-SOT2-Ex2.IO KFD2-SOT2-Ex2.IO-Y181008 KFD2-SR2-Ex2.2S KFD2-SRA-Ex4 KFD2-ST2-Ex1.LB KHA6-SH-Ex1 KCD2-SON-Ex1 
	
		KCD2-SON-Ex1.R1 KCD2-SON-Ex1.SP KCD2-SON-Ex2 KCD2-SON-Ex2.R1 KCD2-SON-Ex2.SP KCD2-SOT-Ex1.LB.SP KCD2-SOT-Ex2.SP 
	
		KCD2-SR-Ex1.LB.SP KCD2-ST-Ex1.LB.SP KCD2-ST-Ex2 KCD2-ST-Ex2.SP KFA5-DU-Ex1.D KFD2-ELD-Ex16 KFD2-SOT2-Ex1.R1 KFD2
	
		-UFC-Ex1.D KFU8-UFC-Ex1.D KFD2-DWB-Ex1.D KFA5-DWB-Ex1.D KFA6-DWB-Ex1.D KFD2-SR2-Ex2.W-SM KFD2-UFT-Ex2.D KFU8-
	
		UFT-Ex2.D KFD2-RO-Ex2 KCD0-SD-Ex1.1245 KFD0-SD2-Ex1.1045 KFD2-SL2-Ex1 KFD2-SL2-Ex1.B KFD2-SL2-Ex1.LK KFD2-SL2-
	
		Ex2.B KFD0-SD2-Ex2.1045 KFD2-SL2-Ex2 KFD2-VM-Ex1.35.L KFD0-SD2-Ex1.10100 KFD0-SD2-Ex1.1065 KFD0-SD2-Ex1.1180 
	
		KFD0-SD2-Ex2.1245 KFD2-RCI-Ex1 KFD2-SL2-Ex1.LK.1045 KFD2-SL2-Ex1.LK.1270 KFD2-SL2-Ex1.LK-Y1 KCD0-SD-Ex1.1245.SP
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-UT2-Ex1 KFD2-GUT-Ex1.D KFD2-UT2-Ex1 KFD2-UT2-Ex2 KFD0-CC-Ex1 KFD0-TR-Ex1 KFD0-TT-Ex1 KFD2-PT2-Ex2 KFD2-PT2-
	
		Ex1-1 KFD2-PT2-Ex1-4 KFD2-PT2-Ex1-5 KFD2-PT2-Ex1-6-Y112844 KFD2-UT2-Ex1-1 KFD2-UT2-Ex2-1 KFD2-WAC2-Ex1.D KFU8-
	
		GUT-Ex1.d KFD2-PT2-Ex1-Y98312 KFD2-WAC2-Ex1.D-Y1 KFD2-CRG2-Ex1.D KFD2-GUT-Ex1.D KFD2-GU-Ex1 KFD2-WAC2-Ex1.D KFU8
	
		-CRG2-Ex1.D KFU8-GUT-Ex1.D KFD2-WAC2-Ex1.D-Y1 KCD2-SCD-Ex1 KFD2-SCD-Ex1.LK KFD2-SCD2-Ex1.LK KFD0-CS-Ex1.51P KFD2
	
		-SCD2-Ex2.LK KFD2-CD-Ex1.32 KCD2-SCD-Ex1.HC KCD2-SCD-Ex1.SP KFD0-CS-Ex1.50P KFD0-CS-Ex1.53 KFD0-CS-Ex2.50P KFD0-
	
		CS-Ex2.51P KFD2-CD2-Ex1 KFD2-CD2-Ex2 KFD2-SCD2-Ex1-Y1 KFD2-SCD2-Ex2-Y1 KCD2-SCD-Ex1.HC.SP KFD0-CS-Ex2.53 KFD0-
	
		CS-Ex2.51P-Y107439 KCD2-STC-Ex1 KFD2-CRG2-Ex1.D KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex2 
	
		KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.H KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.DE KCD2-STC-Ex1.ES KCD2-STC-Ex1.HC KCD2-STC-
	
		Ex1.SP KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.4S KFD2-STC3-Ex1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y229428 
	
		KFD2-STV3-Ex1-1 KFD2-STV3-Ex1-2 KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 KFD2-STV4-Ex1.2O-1 KFU8-CRG2-Ex1.D KCD2-STC-
	
		Ex1.ES.SP KCD2-STC-Ex1.HC.SP KFD2-HLC-Ex1.D.2W KFD2-STV4-Ex1.2O-2 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KFD2-VR4-Ex1.26 KFD0-CS-Ex1.51P KFD0-SCS-Ex1.55 KCD2-RR-Ex1-Y1 KFD2-VR2-Ex1.50M KFD0-CS-Ex1.50P KFD0-CS-Ex1.52 
	
		KFD0-CS-Ex1.53 KFD0-CS-Ex1.54 KFD0-CS-Ex2.50P KFD0-CS-Ex2.51P KFD0-CS-Ex2.52 KFD0-CS-Ex2.54 KFD2-FF-Ex2.RS232 
	
		KFD2-VR-Ex1.12 KFD2-VR-Ex1.18 KFD2-VR-Ex1.19 KFD2-VR-Ex1.19-Y109129 KFD2-VR2-Ex1.500M KCD2-RR-Ex1 KCD2-RR-Ex1.SP 
	
		KFD0-CS-Ex1.54-Y2 KFD0-CS-Ex2.53 KFD0-CS-Ex2.51P-Y107439
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		M-LB-2.275TN.D M-LB-2.275TT.D M-LB-1.275.D M-LB-2.150TN.D M-LB-2.255.T3.D M-LB-2.30.T3.D M-LB-3.275TNC.D M-LB-4.275TNS.D 
	
		M-LB-4.275TT.D M-LB-1.150.D M-LB-1.150.M M-LB-1.275.M M-LB-1.NPE.M M-LB-2.150.T3.D M-LB-2.150.T3.M M-LB-2.255.T3.M M-LB-
	
		2.30.T3.M M-LB-3.150TNC.D M-LB-4.150TNS.D P-LB-1.B.12 P-LB-1.C.123 P-LB-1.A.13 P-LB-1.D.1234 P-LB-2.A.1346 P-LB-2.B.1245 P-
	
		LB-2.D.123456 P-LB-1.E.23 P-LB-1.F.1236 P-LB-2.C.2356 K-LB-1.30 K-LB-1.30G K-LB-1.6G K-LB-2.30 K-LB-2.3G K-LB-2.6 K-LB-2.6G 
	
		K-LB-1.6 FN-LB-I FP-LB-I FS-LB-I
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-SOT2-EX1.LB KFD2-STC4-EX1.H KFD2-UFT-EX2.D KFD2-STC4-EX1.2O-Y122582 KFD2-STC4-EX1-Y122583 KFD2-SH-EX1 KHA6-SH-EX1 KFD2-STC4-1 KFD2-STC4-1.20 KFD2-STC4-EX1 KFD2-STC4-EX1.H KFD2-STC3-EX1 KFD2-GUT-EX1.D K-CJC-BU KFA6-SR2-EX1.W.LB KFU8-FSSP-1.D KFD2-PT2-EX1 KFD2-PT2-EX1-5 K-ADP-USB KFD2-CRG2-EX1.D KFD2-CRG2-1.D UPR-03 UPR-05 KFD2-STC1-EX1 KFD2-WAC2-EX1.D KFD2-EB2.R4A.B KFD2-SOT2-EX2 KFD2-SOT2-EX1.LB KFD2-SL2-EX1 KFD2-SL2-EX2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-EX2 WE77/EX2 WE77/EX1 WE77/EX1-BI KFD2-ST2-EX2 KFD2-ST2-EX1.LB KFD0-CS-EX2.51P KFD2-VD-EX1.1560 KFD2-VR4-EX1.26 HIC2025 HIC2031 KFA5-SR2-EX2.W KFA6-SR2-EX2.W KFD2-GUT-EX1.D KFD2-GUT-1.D KFD2-STC4-Ex2 KFD2-DWB-1.D KFU8-DWB-1.D KFA6-DWB-EX1.D KFD2-VR2-Ex1.50M KFD0-CS-EX1.54 KFD0-CS-EX2.54 KCD2-SR-EX2 KFD2-STC4-2 KFD2-ST-EX2 KFD0-SD-EX1.1065 KHD2-FF-EX2.P-RS232 KFD2-EB2 KFD2-CR4-1 KFD2-CR4-1.20 KFD2-RR-EX1 KFD2-SOT2-EX1.LB KFD2-STV4-EX1-1 KCD2-STC-EX1 KFD2-ST2-EX1.LB KFD2-CRG2-1.D KFD0-SD2-EX1.1045 KCD2-E KCD2-E2 KCD2-RR-EX1 KFD2-STV1-EX1-1 KFD0-RO-EX2 KCD2-SCD-1 KFD0-TR-EX1 KCD2-SR-EX1.LB KCD0-SD-EX1.1245 KFD0-RSH-1 KFD2-CD2-EX1 KFD2-CD2-EX2 KFD0-RSH-1-Y2 KFD2-CD-EX1.32-8 KCD0-SD-EX1.1245 Z954 Z728 Z787 Z787.H Z715 Z788 Z966 Z966.H Z964 Z728 Z728.H
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		HD2-FBPS-1.25.360 ELS-1 HCD2-FBPS-1.500 HD2-DM-A HD2-GTR-4PA KT-MB-GT2AD.FF KT-MB-GT2AD.FF.IO R-SP-E12 HCD2-FBPS-1.23.500 EI-
	
		0D2-10Y-10B FDH-1 HD2-DM-A.RO HD2-DM-B KFD2-BR-1.PA.1500 KFD2-BR-Ex1.3PA.93 KLD0-SAA KLD2-FBPS-1.25.360 KLD2-PR-1.IEC KT-MB-DMA 
	
		KT-SRT-FF KT-SRT-PA USB-FBPS-1.11.45.NI BP-FBPS-1.30.1 FBTA-228-BPFB-R-8R HD2-GTR-4PA.PN KLD2-FBPS-1.12.220 FBTA-228-BPFB-8 
	
		FBTA-228-BPFB-R-4R HD2-FBPS-1.17.500 HD2-FBPS-1.23.500 HD2-FBPS-1.25.360 HD2-FBPS-1.500 KLD2-PR-Ex1.IEC KLD2-PR-Ex1.IEC1 MB-
	
		FB-4R.HO.SC EI-0D2-10Y-10B-Y1 DP-LBF-I1.36. F*-FT-Ex1 F*-FT-Ex1.D.IEC F*-FT-Ex1.I.IEC F*-LBF-D1.32 F*-LBF-I1.32 
	
		F.FB0.P**.A**.1.0.***.***.**** F.FB0.S**.A**.1.0.***.***.**** F.FB1.P14.A**.1.*.***.***.**** MBHC-FB-8R.HSC MBHC-FB-8R.RH 
	
		MBHC-FB-8R.YO R2-SP-IC R4D0-FB-IA R8D0-MIO-Ex12.FF R8D0-MIO-Ex12.PA RD0-FB-Ex4. RD0-TI-Ex8.FF. RD0-TI-Ex8.PA. SCP-LBF-IA1.36.IE
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		HID2025 HID2026 HID2061 HID2061 HID2062 HID2062 HID2071 HID2071 HID2072 HID2072 HID2033 HID2034 HID2031 HID2032 HID2037 
	
		HID2038 HID2029 HID2029 HID2030 HID2030 HID2029SK HID2030SK HID2035 HID2036 HID2000 HID2038Y HID2012 HID2038 HID2024 HID2096 
	
		HID2025 HID2026 HID2025SK HID2026SK HIC2095 HIC2065 HIC2027 HIC2068 HIC2077 HIC2000 HIC2025ES HIC2031HC HIC2025HC HID2025ES 
	
		HIC2027DE HID2081 HID2082 H-CJC-SP-8 H-CJC-SC-8 HIC2031 HIC2025 HID2026 HIC2077-Y1 HIC2441 H-CJC-PT100 HIC2025 HIC2031 HIC2027 
	
		HIC2027DE HIC2081 HID2025ES HIC2025ES
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-SCD-1   KCD2-SCD-EX1  KCD2-SR-EX1.LB    KCD2-SR-EX2   KCD2-STC-1   KCD2-STC-EX1   KCD2-STC-EX1.2O  KCD2-UT2-EX1
	
		KFA6-SR2-Ex1.W  KFD0-SD2-Ex1.1045  KFD2-CD2-EX1  KFD2-CRG2-EX1.D  KFD2-DWB-1.D  KFD2-EB2   KFD2-GU-1   KFD2-GUT-Ex1.D
	
		KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2  KFD2-SR2-Ex1.W.LB  KFD2-SR2-Ex2.W  KFD2-ST2-Ex2  KFD2-STC4-1 
	
		KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1  KFD2-UT2-Ex2 KFD2-VR4-EX1.26 KFD2-SR2-Ex2.W
	
		KFD2-SL2-Ex1 KFD2-SR2-Ex1.W KFD2-STC4-Ex1 KFD2-SR2-EX.1.W.LB  KFD2-EB2.R4A.B KFD2-SCD2-EX1.LK KFD2-SR2-EX2.W
	
		KFD2-SL2-EX2.B  KFD0-TT-EX1  KFD0-TR-EX1  KFD2-STC4-EX2  KFD2-UFC-EX1.D  KFD2-SCD2-EX2-LK  KFD2-CD-EX1.32-15
	
		KFD2-STC4-EX1.2O KFD2-SH-EX1.T.OP KFD2-SR2-EX2.2S  KFD2-BR-1.PA.93 KFD2-UT2-EX2 KFD2-UFC-EX1.D KFD0-SD2-EX1.1045
	
		KFD2-SOT2-EX1.LB KFD2-STC4-EX1.20  KFD2-STC4-1.20 KFD2-SCD2-EX2.LK KFD2-SCD2-2.LK KFD2-SH-EX1 KFD0-SD2-Ex2.1245
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KFD2-SL2-Ex1.LK KFD2-BR-Ex1.3PA.93 KFD2-CD2-EX2 KFD2-UT2-EX2 KFD2-STC4-EX1.2O KFD2-CR4-1.2O KFD2-CD2-EX1 KFD2-SL2-EX2 KFD2-
	
		PR-1.IEC KFD2-WAC2-EX1.D KFD2-UFT-EX2.D KFD2-UFC-1.D KFD-STC4-EX1.2O.DE KFD2-SCD2-EX1 KFD2-PT2-Ex1 KFD2-SR2-EX2.2S KFD0-SD2
	
		-EX1.1045 KCD2-E2L KCD2-STC-EX1 KFD2-SR2-EX1.W KFD2-SCD2-EX1-LK KCD2-SCD-EX1 KFD2-UT2-EX1 KFD2-VR4-EX1.26 KFD2-SR2-EX1.W.LB 
	
		KFDO-RSH-1 KFD2-GS-1.2W KFD2-EB.R4A.B KFD0-SCS-EX1.55 KFD2-EX1.32 KFD2-STC4-Ex1-Y1. KFD2-SR2-EX2.2S KFD2-SCD2-EX2.LK
	
		KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB  KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-
	
		Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP 
	
		KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-
	
		STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 
	
		KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 
	
		KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 
	
		KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-STC-Ex1 KCD2-STC-Ex1.ES KFD2-CRG2-Ex1.D KFD2-HLC-Ex1.D KFD2-HLC-Ex1.D.2W KFD2-STC4-Ex1 KFD2-STC4-Ex1.2O KFD2-STC4-
	
		Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STC4-Ex2 KFU8-CRG2-Ex1.D KCD2-STC-Ex1.2O KCD2-STC-Ex1.2O.ES KCD2-STC-Ex1.ES.SP KCD2-STC-Ex1.SP 
	
		KFD2-STC3-Ex1 KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.ES KFD2-STC4-Ex2-Y1 KFD2-STC5-Ex1 KFD2-STC5-Ex1.2O KFD2-
	
		STC5-Ex1.2O.H KFD2-STC5-Ex1.H KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STC5-Ex2 KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 
	
		KFD2-STV5-Ex1-1 KCD2-STC-Ex1.2O.DE KFD2-HLC-Ex1.D.4S KFD2-STV4-Ex1.2O-2 KCD2-STC-Ex1.HC KCD2-STC-Ex1.HC.SP KFD2-STC4-Ex1 
	
		KFD2-STC4-Ex1-Y1 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y1 KFD2-STC4-Ex1.2O.H KFD2-STC4-Ex1.H KFD2-STV4-Ex1-1 KFD2-STV4-Ex1-2 
	
		KFD2-STV4-Ex1.2O-1 KFD2-STV4-Ex2-1 KFD2-STV4-Ex2-2 KFD2-STV4-Ex1.2O-2 KFD2-STC3-Ex1 KCD2-STC-Ex1-Y1
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-1 KCD2-STC-EX1 KCD2-STC-EX1.2O KCD2-UT2-EX1 KFA6-SR2-Ex1.W KFD0-SD2-Ex1.1045 KFD2-CD2-EX1 KFD2-CRG2-EX1.D KFD2-DWB-1.D KFD2-EB2 KFD2-GU-1 KFD2-GUT-Ex1.D KFD2-SCD2-EX2.LK KFD2-SH-EX1.T.OP KFD2-SOT2-Ex2 KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-ST2-Ex2 KFD2-STC4-1 KFD2-STC4-EX2 KFD2-STC4-Ex2 KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-Ex2 KFD2-VR4-EX1.26 KFU8-FSSP-1.D KCD2-SR-Ex1.LB KCD2-SR-Ex2 KFA6-DU-Ex1.D KFA6-ER-Ex1.W.LB KFA6-SOT2-Ex2 KFA6-SR2-Ex1.W KFA6-SR2-Ex1.W.LB KFA6-SR2-Ex2.W 
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		 
	
		KFA6-SR2-Ex2.W.IR KFD2-DU-Ex1.D KFD2-ELD-Ex16 KFD2-ER-Ex1.W.LB KFD2-SH-Ex1 KFD2-SH-Ex1.T.OP KFD2-SOT3-Ex1.LB KFD2-SOT3-
	
		Ex1.LB.IO KFD2-SOT3-Ex2 KFD2-SOT3-Ex2.IO KFD2-SR2-Ex1.W KFD2-SR2-Ex1.W.LB KFD2-SR2-Ex2.W KFD2-SR3-Ex2.2S KFD2-SRA-Ex4 KFD2-
	
		ST3-Ex1.LB KFD2-ST3-Ex2 KHA6-SH-Ex1 KCD2-SON-Ex1 KCD2-SOT-Ex1.LB KCD2-SOT-Ex2 KCD2-SOT-Ex2.SP
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-SR-Ex1.LB.SP KCD2-SR-Ex2.SP KCD2-ST-Ex1.LB KCD2-ST-Ex2 KFA5-SOT2-Ex2 KFA5-SR2-Ex1.W KFA5-SR2-Ex1.W.LB KFA5-SR2-Ex2.W 
	
		KFA5-SR2-Ex2.W.IR KFD2-SH-Ex1.T KFD2-SOT3-Ex2.IO-Y1 KCD2-SON-Ex1.R1  KCD2-SON-Ex1.SP KCD2-SON-Ex2 KCD2-SON-Ex2.R1 KCD2-SON-
	
		Ex2.SP KCD2-SOT-Ex1.LB.SP KCD2-ST-Ex1.LB.SP KCD2-ST-Ex2.SP KFA4-SR2-Ex2.W KFA5-DU-Ex1.D KFA4-SR2-Ex1.W KFA4-SR2-Ex1.W.LB 
	
		KFD2-SOT2-Ex1.LB KFD2-SOT2-Ex1.LB.IO KFD2-SOT2-Ex2 KFD2-SOT2-Ex2.IO KFD2-SOT2-Ex2.IO-Y181008 KFD2-SR2-Ex2.2S KFD2-ST2-Ex1.LB 
	
		KFD2-ST2-Ex2 KFD2-STC4-EX1 KFD2-SR2-EX1.W KFD2-SR2-EX2.W KFD2-CD-EX1.32 KFD2-UT2-EX1. KFD2-ST-EX1 KFD2-UFC-EX1.D KFA5-SR2-EX2.W KFA5-SR2-EX1.W KFA6-SR2-EX2.W KFA5-SR2-EX1.W KFD2-ST-EX1 KFD2-SOT2-EX1 KFU8-UFC-EX1.D KFD2-CD-EX1.32 KFU8-FSSP-1.D KFA6-DWB-EX1.D 
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KFD2-DWB-EX1.D KFA5-SR2-EX1,W KFA5-SR2-EX2,W KFD2-VR4-EX1.26 KFD2-STC4-EX1.20 KFD2-SOT2-EX2 KFD2-ST2-EX1.B KFD2-DWB-EX1.D 
	
		KFD2-UFC-EX1.D KFA6-STR-1.24.500 KFD2-UT2-1 KFD2-UT2-2 KFD2-CD-1.32 KFD2-SOT2-EX1.LB KFA6-SR2-EX1.LB KFA6-SOT2-EX2 KFU8-
	
		FSSP-1.D KFU8-UFC-EX1,D KFU8-UFT-EX2.D KFA6-DWB-EX1.D KFD0-SCS-EX1.55 KFD2-STC4-EX2 KFD2-STC4-EX1Y125882 KFD2-UT2-EX2 UPR-03 
	
		KFD2-EB2.B4.AB KFD2-CD-EX1.32 KFD2-STC4-EX1 KFD2-UT2-EX1 KFD2-SR2-Ex1.W KFD2-SCD-EX1.LK KFD2-SOT2-EX2 KFD2-STC4-EX2 KFD2-
	
		SR2-Ex2.W KFD2-SR2-Ex1.W KFD2-STC4-EX1.2O KFD0-SCS-EX1.55 KFU8-UFC-EX1.D KFD2-SOT2-EX2 KFD2-STC4-EX1 KFD2-UT2-EX2 KFD2-VR4-
	
		EX1.26 KFD2-EB2.R4A.B KFD2-BR-1.PA.93 KFU8-DWB-1.D KFU8-DW-1.D KFU8-UFT-EX2.D Z787.H UPR-03
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-SR-EX1.LB KFD2-SR2.Ex1.W KFA5-SR2-Ex1.W KFA6-SR2-Ex1.W KFD2-SR2-Ex1.W.LB KFA5-SR2-Ex1.W.LB KFA6-SR2-Ex1.W.LB KCD2-SR-
	
		EX2 KFD2-SR2-Ex2.W KFA5-SR2-Ex2.W KFA6-SR2-Ex2.W KFA5-SR2-EX2.W.IR KFA6-SR2-EX2.W.IR KFD2-SR2-Ex2.2S KFD2-SRA-Ex4 KFD2-SRT-
	
		Ex1 KFD2-SR-Ex1.4S.LK KFD2-DU-Ex1.D KFA5-DU-EX1.D KFA6-DU-EX1.D KFD2-ER-EX1.W.LB KFA5-ER-EX1.W.LB KFA6-ER-EX1.W.LB KFD2-ST2
	
		-Ex1.LB KFD2-ST2-Ex2 KFD2-SOT2-Ex1.LB KFD2-SOT2-EX1.LB.IO KFD2-SOT2-Ex1.N KFD2-SOT2-Ex2 KFA5-SOT2-Ex2 KFA6-SOT2-Ex2 KFD2-
	
		SOT2-Ex2.IO KFD2-SH-Ex1 KFD2-SH-Ex1.T.OP KHA6-SH-Ex1 KFD2-SR2-EX2.W.SM KFD2-DWB-Ex1.D KFA5-DWB-EX1.D KFA6-DWB-EX1.D KFD2-
	
		UFC-EX1.D KFU8-UFC-EX1.D KFD2-UFT-Ex2.D KFU8-UFT-Ex2.D KFD0-SD2-Ex1.1045 KFD0-SD2-Ex2.1045 KCD0-SD-EX1.1245 KFD0-SD2-
	
		EX2.1245 KFD0-SD2-Ex1.1065 KFD0-SD2-Ex1.1180 KFD0-SD2-Ex1.10100 KFD2-SL2-EX1 KFD2-SL2-EX1.B KFD2-SL2-Ex1.LK KFD2-SL2-Ex2 
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
		 
	
		KFD2-SL2-Ex2.B KFD2-VM-Ex1.35 KFD2-VM-Ex1.35.L KFD0-RO-Ex2 KCD2-STC-EX1 KFD2-STC4-Ex1 KFD2-STC4-Ex1-Y122583 KFD2-STC4-Ex1.H 
	
		KFD2-STV4-EX1-1 KFD2-STV4-EX1-2 KFD2-STC4-Ex1.2O KFD2-STC4-Ex1.2O-Y122582 KFD2-STC4-Ex1.2O.H KFD2-STV4-EX1.2O-1 KFD2-STV4-
	
		Ex1.2O-2 KFD2-STC4-Ex2 KFD2-STC4-Ex2-Y203646 KFD2-STV4-EX2-1 KFD2-STV4-EX2-2 KFD2-STC3-Ex1 KFD2-STV3-Ex1-1 KFD2-STV3-Ex1-2 
	
		KFD2-CRG-Ex1.D KFU8-CRG-Ex1.D KFD0-CS-Ex1.52 KFD0-CS-Ex2.52 KFD0-CS-Ex1.54 KFD0-CS-Ex2.54 KFD2-VR2-Ex1.50m KFD2-VR-Ex1.500m 
	
		KFD2-VR-Ex1.12 KFD2-VR-Ex1.18 KFD2-VR-Ex1.19 KFD2-VR4-EX1.26 KFD0-CC-Ex1 KFD2-WAC2-EX1.D KFD2-UT2-Ex1 KFD2-UT2-Ex1-1 KFD2-
	
		UT2-Ex2 KFD2-UT2-Ex2-1 KFD0-TR-Ex1 KFD0-TT-Ex1 KCD2-RR-Ex1 KFD2-GU-Ex1 KFD2-GUT-Ex1.D KFU8-GUT-EX1.D KFD2-UT2-Ex1 KFD2-UT2-
	
		Ex1-1 KFD2-UT2-Ex2 KFD2-UT2-Ex2-1 KFD2-RR-Ex1 KFD2-PT2-Ex1 KFD2-PT2-Ex1-1 KFD2-PT2-Ex1-4 KFD2-PT2-Ex1-5 KFD0-RC-Ex1 KFD2-
	
		HLC-EX1.D KFD2-HLC-EX1.D.2W KFD2-HLC-EX1.D.4S KFD2-FF-Ex2.RS232 KFD2-ELD-Ex16
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		KCD2-SCD-EX1 KFD2-SCD-Ex1.LK KFD2-SCD2-Ex1.LK KFD2-CD2-EX1 KFD2-CD-EX1.32 KFD2-SCD2-EX2.LK KFD2-CD2-EX2 KFD0-SCS-Ex1.55 
	
		KFD0-CS-Ex1.50P KFD0-CS-Ex1.51P KFD0-CS-Ex1.53 KFD0-CS-Ex2.50P KFD0-CS-Ex2.51P KFD0-CS-Ex2.53 KFD2-EB2.R4A.B KFD2-EB2 KFA6-
	
		STR-1.24.500 KFA6-STR-1.24.4 UPR-03 UPR-03-S UPR-05 UPR-05-S UPR-I UPR-E K-MS K-CJC-BU KF-FKC-3G2B KF-FKC-5B KF-FKC-5G K-
	
		500R0%1 KCD0-LGH KFD0-LGH KFD0-LGH-GN KFD0-LGH-Y34868 F-KD-Ex2 F-KDR-Ex2 IS01 F-MPN-1 K-ADP1 K-ADP-USB
	
		Pepperl+Fuchs KFA6-SR2-Ex1.W.LB Switch Amplifier KFA6-SR2-Ex1.W.LB Safety Barriers Arrived
	
		We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
	
		We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL, Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Delta,Sick,CKD,Moog etc.
	
		Contact:
	
		HONGKONG XIEYUAN TECH CO., LIMITED
	
		Email:becky@hkxytech.com   Web:www.hkxytech.com
	
		Mobile:+86-15972186287(Whatsapp & Wechat)
 
			 
		