A2FV50D-A412000
Model A2FV50D Duplexed Field Control Unit (for N-IO, 19-inch Rack Mountable)
Suffix Codes
-A Standard type (for CP471) (*1)
4 Dual-redundant Vnet/IP, dual-redundant power supply
1 Always 1
2 220 - 240 V AC power supply (*4)
0 With no explosion protection
0 Basic type
0 Always 0
Duplexed Field Control Unit
Model A2FV50D Duplexed Field Control Unit (for N-IO, 19-inch Rack Mountable)
Suffix
Codes
-A Standard type (for CP471) (*1)
-S Standard type (for CP461) (*3)
4 Dual-redundant Vnet/IP, dual-redundant power supply
1 Always 1
1 100 - 120 V AC power supply (*4)
2 220 - 240 V AC power supply (*4)
4 24 V DC power supply (*4)
0 With no explosion protection
1 With explosion protection
0 Basic type
1 With ISA Standard G3 option
0 Always 0
Option
Code
/ATDOC Explosion Protection Manual (*5)
/MRN With Marine Standards (*2)
*1: CP471 operates with CENTUM VP R6.01 or later version of Control Function for Field Control Station. Be sure to apply the
software patch for supporting CP471 for CENTUM VP R6.01, R6.02, R6.03, and R6.04. CP471 can be combined with the
style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN.
*2: Select the option code “/MRN” if A2FV50 with marine standards is required.
*3: Unavailable for ordering A2FV50D with CP461 due to the supply ends on October 19, 2019. Existing CP461 can be
replaced with CP471. Replacement from CP461 to CP471 is prohibited to perform by a user.
This replacement must be done by the service engineer authorized by Yokogawa Electric Corporation. CP471 can be
combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN.
*4: To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet.
*5: Select the option code “/ATDOC” to follow the ATEX Directive when any of N-IO components are used for explosion
protection.
More Yokogawa Products for your choice:
AAI143-H50/A4S00
AAI143-S00, replaced by:AAI143-S50
AAI543-H50/K4A00
AAI543-S00 replacement AAI543-S50
AAT145-S00
AIP601
9548FA (HHR-21AHF2A1)
A1BA4D-05
A1BD5D-05
A2EE1A-T
A2EN402-S0000
A2EN404-S0000
A2FV50D-A412000
A2KLF00-1С60
A2KPB00-1C62
A2SAM105-H000
A2SAM105-H000 S2
AAI141-H00
AAI141-H00/K4A00
AAI141-H50
AAI141-H50 AAI141-H00
AAI141-H50/K4A00
AAI141-H50/K4A00 AAI141-H00/K4A00
AAI141-H50/K4A00 AAI143-H50/K4A00
AAI141-S00
AAI141-S50
AAI141-S50/K4A00
AAI143
AAI143 AAI143-H50
AAI143-H00
AAI143-H00 S1
AAI143-H50
AAI143-H50/A4S00
AAI143-H50/A4S10+ ATA4S-10
AAI143-H50/K4A00
AAI143-H53
AAI143-H53 AAI143-H50
AAI143S,complete model:AAI143-S50
AAI143-S00
AAI143-S50
AAI143-S50/A4S00
AAI143-S50/A4S00 with ATA4S-00
AAI143-S50/A4S00 with ATA4S-00
AAI143-S50/A4S10
AAI143-S50/K4A00
AAI543-H00
AAI543-H00 S1
AAI543-H00,upgraded model: AAI543-H50
AAI543-H00/A4S00
AAI543-H00/K4A00 replacement AAI543-H53/K4A00
AAI543-H00/K4A00,upgraded model: AAI543-H50/K4A00
AAI543-H50
AAI543-H50/A4S00
AAI543-H50/A4S10+ATA4S-10
AAI543-H50/K4A00
AAI543-H53
AAI543-H53 AAI543-H50
AAI543-H53/K4A00
AAI543-H60
AAI543-H60/K4A00
AAI543S,complete model:AAI543-S50
AAI543-S00
AAI543-S50
AAI543-S50/A4S10 with ATA4S-10
AAI543-S50/A4S10, ATA4S-10
AAI543-S50/A4S10, ATA4S-10
AAI543-S50/A4S11, correct model:AAI543-S50/A4S10
AAI543-S50/K4A00
AAI841-S50/K4A00
AAl141-H50/K4A00 replacement AAI141-H00/K4A00
AAl141-S50/K4A00
AAl841-S50/K4A00
AAM10
AAP135-S00
AAR145-S50
AAT145-S50
AAV141-S00
AAV144-S50/A4S10
AAV144-S50/A4S10 + ATA4S-10
AAV144-S50/A4S10 + ATA4S-10
ACM12
ADCV01
ADM12C
ADM52C-2
ADV151-E00
ADV151-E50
ADV151-E50 ADV151-E00
ADV151-E60/D5A00
ADV151-P00
ADV151-P00 S2
ADV151-P50
ADV151-P50/CCC01 ADV151-P50
ADV151-P50/D5A00
ADV151-P60/B5S00
ADV161-P00
ADV161-P50
ADV169P
ADV169-P00
ADV169-P01
ADV169-P50
ADV551-P00 ADV551-P50
ADV551-P00 S2
ADV551-P50
ADV551-P60/D5S00
ADV561-P50
ADV569P
ADV569-P00
ADV569-P01
ADV569-P50
ADV869-P00
ADV869-P01
AEA4D-05
AEP7D-25
AFS40D, CP345
AFV30D-A41252
AFV30D-S41252
AFV30D-S41252 AFV30D-A41252
AIP504-10
AIP504-50
AIP571
AIP601
AIP601-S1
AIP602-S2
AIP827-2
AIP830-101
AIP830-111/EIM
AKB331-M010/HF AKB331-M010
AKB337-15
AKB337-M010
AKB337-M020 L=20m
ALE111 ALE111-S50
ALE111-S50
ALE111-S51
ALE121-S50
ALE121-S50 ALR121-S50
ALP111-S01
ALP121-S00
ALR111-S50 replacement ALR111-S00
ALR121-S00
ALR121-S50
ALR121-S50 replacement ALR121-S53
ANB10D-425/CU2N
ANB10D-425/CU2N/NDEL
ANB10D-425/CU2T
ANB11D-425/BU2A
ANT401-50/CU1T
ANT401-5E, code E ANT401-50
GCRV-GBARS88N0151/A100/B036
GRVACA-677FA
GRVSFP-675FA
GRVSW-660FA
GRVSW-660FA replacement Hirschmann MACH104-20TX-FR
GRVSW-663FA
GRVSW-664FA
GRVSW-665FA
GRVSW-666FA
GRVSW-667FA
GRVSW-668FA
GRVSW-669FA
GRVSW-670FA
GRVSW-671FA
GRVSW-672FA
GRVSW-673FA
We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
Contact: