fieldcommunicator

Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA5

Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA550

 


 

Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA550

Yokogawa YHC5150X HART Communicator was discontinued, It's replaced By Yokogawa CA550 Multi-Function Process Calibrator.

Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA550

The CA500 and CA550 are high-performance, multi-function calibrators designed for use in multiple applications. Featuring useful functions for field work, these multi-function calibrators help you calibrate field instruments with improved source and measurement accuracy. 
 
Two models are available, offering two different levels of accuracy:
 
The CA500 achieves an accuracy of 0.015% (DC current), 0.020% (resistance), and 0.3˚C (RTD). 
The CA550 achieves an accuracy of 0.010% (DC current), 0.015% (resistance), and 0.1˚C (RTD).
 
 
 
Multi-function     Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA550
 
  • Sources and measures DC voltage, DC current, RTD, TC, resistance, frequency and pulse signals
  • Corresponds to 17 types of TC standard (JIS/IEC/DIN/ASTM/GOST R)
  • Corresponds to 14 types of RTD standard (JIS/IEC/GOST R)
  • Multiple source patterns
  • Linear sweep function
  • Continuously Source from 0% to 100%
 
Step sweep function
Change output in a staircase (step) pattern by specifying the number of steps. (The number of steps can be set from 2 to 20)
 
Program sweep function
Users can set the desired output value (%) and number of steps. (10 steps for CA500, 20 steps for CA550)
 
 
 
Functions       Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA550
 
Automatic input/output testing *CA550 only
(Program sweep)
 
Automatic input/output testing is possible by setting source values for each step for a calibration target. Calibration results such as generated value, measured value, error rate, date/time, and pass/fail are saved in CSV format in the CA550 main unit.
 
By connecting the CA550 to a PC using a standard USB cable, the instrument can be recognized as a mass-storage device for data to be transferred to the PC.
 
HART Communication Protocol *CA550 only
Version update will be available in June, 2020.(Free)
 
The following items are supported by HART communication function:
 
  • TagNo.                                                                                                                              Read
  • PV value (including reading of PV %value, AO value, SV value, TV value, QV value)    Read
 
  • LRV (Lower limit of range)      Read and Write
  • URV (Upper limit of range)     Read and Write
  • Damping                                 Read and Write
 
  • Trimming of 4 mA          Write
  • Trimming of 20 mA        Write
 
*Please note that not all commands are supported by HART communication.
*TagNo acquisition function is available in BRAIN communication. No other functions are available.



Easy-to-view Display
 
CA500 features a Reflective LCD, providing improved outdoor visibility. Main display (generated/measured values) and Sub display (%, mV, Ω, etc.) allow required information at a work site to be confirmed at a glance.
 
 
Wiring information display function
 
A wiring diagram is displayed according to the function selected. This function allows a user to perform wiring while referring to a wiring diagram and prevents mis-wiring.
 
Thermocouple generation using TC Mini Plug
 
Using a TC Mini Plug together with a compensating lead wire enables generation of thermal electromotive force without an external RJ sensor.*
* A compensating lead wire needs to be prepared by customer.
 
 
Easy-to-use key operation
 
Easy-to-use key operation0%/100% keys
The source can be easily switched between 0% and 100% of range. Users can also set a desired value.
 
UP/DOWN keys
The output is changed in preset steps by pressing UP or DOWN key.
 
 
Operation key layout
Keys related to generation and measurement are arranged collectively to allow easy and intuitive operation.
 
 
SQUARE ROOT output
For 4-20 mA, 1-5 V ranges, users can choose between LINEAR and SQUARE ROOT output.


Yokogawa YHC5150X HART Communicator Replaced By Yokogawa CA550

We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We have bigger advantages of Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.
 
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)
Previous:New Arrival of Emerson TREXCFPNAWS3S AMS Trex Device Communi Next:New Arrival of Omron H5L-A Time Switches H5L-A Daily Time Sw