ABB TTH300E1HBS TTH300 Head-Mount Temperature Transmitters
ABB TTH300E1HBS TTH300 Head-Mount Temperature Transmitters
ABB TTH300 Head-mount temperature transmitter supports all communication protocols including Hart, Profibus and Foundation fieldbus, comply with SIL2/SIL3 approval in accordance with IEC 61508 for Hart protocol.
ABB TTH300E1HBS TTH300 Head-Mount Temperature Transmitters
Sensor |
Measuring range limits |
Minimum span |
Digital measuring accuracy (24-bit AD-converter) |
DA measuring accuracy (16-bit DA) |
|
Resistance thermometer/resistor |
|||||
DIN IEC 60751 |
Pt10 (a=0.003850) |
-200 ... 850 °C (-328 … 1562 °F) |
10 °C (18 °F) |
± 0.80 °C (± 1.44 °F) |
± 0.05 % |
Pt50 (a=0.003850) |
± 0.16 °C (± 0.29 °F) |
± 0.05 % |
|||
Pt100 (a=0.003850 |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
Pt200 (a=0.003850) |
± 0.24 °C (± 0.43 °F) |
± 0.05 % |
|||
Pt500 (a=0.003850) |
± 0.16 °C (± 0.29 °F) |
± 0.05 % |
|||
Pt1000 (a=0.003850) |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
JIS C1604 |
Pt10 (a=0.003916) |
-200 ... 645 °C (-328 ... 1193 °F) |
10 °C (18 °F) |
± 0.80 °C (± 1.44 °F) |
± 0.05 % |
Pt50 (a=0.003916) |
± 0.16 °C (± 0.29 °F) |
± 0.05 % |
|||
Pt100 (a=0.003916) |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
MIL-T-24388 |
Pt10 (a=0.003920 |
-200 ... 850 °C (-328 ... 1562 °F) |
10 °C (18 °F) |
± 0.80 °C (± 1.44 °F) |
± 0.05 % |
Pt50 (a=0.003920) |
± 0.16 °C (± 0.29 °F) |
± 0.05 % |
|||
Pt100 (a=0.003920) |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
Pt200 (a=0.003920) |
± 0.24 °C (± 0.43 °F) |
± 0.05 % |
|||
Pt1000 (a=0.003920) |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
DIN 43760 |
Ni50 (a=0.006180) |
-60 ... 250 °C (-76 ... 482 °F) |
10 °C (18 °F) |
± 0.16 °C (± 0.29 °F) |
± 0.05 % |
Ni100 (a=0.006180) |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
Ni120 (a=0.006180) |
± 0.05 % |
||||
Ni1000 (a=0.006180) |
± 0.05 % |
||||
OIML R 84 |
Cu10 (a=0.004270) |
-50 ... 200 °C (-58 ... 392 °F) |
10 °C (18 °F) |
± 0.80 °C (± 1.44 °F) |
± 0.05 % |
Cu100 (a=0.004270) |
± 0.08 °C (± 0.14 °F) |
± 0.05 % |
|||
Resistance measurement |
0 ... 500 Ω |
4 Ω |
± 32 mΩ |
± 0.05 % |
|
0 … 5000 Ω |
40 Ω |
± 320 mΩ |
± 0.05 % |
||
Thermocouples / voltages |
|||||
IEC 60584 |
Type K (Ni10Cr-Ni5) |
-270 … 1372 °C (-454 … 2502 °F) |
50 °C (90 °F) |
± 0.35 °C (± 0.63 °F) |
± 0.05 % |
Type J (Fe-Cu45Ni) |
-210 … 1200 °C (-346 … 2192 °F) |
± 0.05 % |
|||
Type N (Ni14CrSi-NiSi) |
-270 … 1300 °C (-454 … 2372 °F) |
± 0.05 % |
|||
Type T (Cu-Cu45Ni) |
-270 ... 400 °C (-454 ... 752 °F) |
± 0.05 % |
|||
Type E (Ni10Cr-Cu45Ni) |
-270 … 1000 °C (-454 … 1832 °F) |
± 0.05 % |
|||
Type R (Pt13Rh-Pt) |
-50 … 1768 °C (-58 … 3215 °F) |
100 °C (180 °F) |
± 0.95 °C (± 1.71 °F) |
± 0.05 % |
|
Type S (Pt10Rh-Pt) |
± 0.05 % |
||||
Type B (Pt30Rh-Pt6Rh) |
-0 … 1820 °C (32 … 3308 °F) |
± 0.05 % |
|||
DIN 43710 |
Type L (Fe-CuNi) |
-200 … 900 °C (-328 … 1652 °F) |
50 °C (90 °F) |
± 0.35 °C (± 0.63 °F) |
± 0.05 % |
Type U (Cu-CuNi) |
-200 … 600 °C (-328 … 1112 °F) |
± 0.05 % |
|||
ASTM E 988 |
Type C |
-0 … 2315 °C (32 … 4200 °F) |
100 °C (180 °F) |
± 1.35 °C (± 2.43 °F) |
± 0.05 % |
Type D |
± 0.05 % |
||||
Voltage measurement |
-125 ... 125 mV |
2 mV |
± 12 μV |
± 0.05 % |
|
-125 ... 1100 mV |
20 mV |
± 120 μV |
± 0.05 % |
Basic Code Selection of ABB TTH300E1HBS TTH300 Head-Mount Temperature Transmitters
Main Code |
Suffix Codes |
Description |
||
TTH300 |
TTH200 Head Mounted Temperature Transmitter |
|||
Explosion Protection |
Y0 |
Without explosion protection |
||
E1 |
ATEX Intrinsic Safety type of protection: Zone 0: II 1 G Ex ia IIC T6, Zone 1 (0): II 2 (1) G Ex [ia] ib IIC T6,Zone 1 (20): II 2 G (1D) Ex [iaD] ib IIC T6 |
|||
E2 |
ATEX Non-sparking type of protection: Zone 2: II 3 G Ex nA T6 |
|||
H1 |
IECEx Intrinsic Safety type of protection: Zone 0: Ex ia IIC T6, Zone 1 (0): Ex [ia] ib IIC T6, Zone 1 (20): Ex [iaD] ib IIC T6 |
|||
L1 |
FM Intrinsic Safety (IS): Class I, Div. 1+2, Groups A, B, C, D, Class I, Zone 0, AEx ia IIC T6 |
|||
L2 |
FM Non-incendive (NI): Class I, Div. 2, Groups A, B, C, D |
|||
R1 |
CSA Intrinsic Safety (IS): Class I, Div. 1+2, Groups A, B, C, D |
|||
R2 |
CSA Non-incendive (NI): Class I, Div. 2, Groups A, B, C, D |
|||
G1 |
GOST Russia - metrological approval |
|||
P2 |
GOST Russia - metrological approval and EAC-Ex, Ex i - Zone 0 |
|||
G3 |
GOST Kazakhstan - metrological approval |
|||
T2 |
GOST Kazakhstan - metrological approval and EAC-Ex, Ex i - Zone 0 |
|||
M5 |
GOST Belarus - metrological approval |
|||
U2 |
GOST Belarus - metrological approval and EAC-Ex, Ex i - Zone 0 |
|||
C1 |
Inmetro Ex ia IIC T6...T4 Ga, Ex ib [ia Ga] IIC T6...T4 Gb Exib [ia IIIC Da] IIC T6...T4 Gb |
|||
S1 |
NEPSI Ex ia IIC T6 |
|||
S5 |
KOSHA Ex ia IIC T6 |
|||
Communication Protocol |
H |
HART |
||
P |
PROFIBUS PA |
|||
F |
FOUNDATION fieldbus |
|||
Configuration |
BS |
Standard configuration |
||
BF |
Customer-specific configuration, except user curve |
|||
BG |
Customer-specific configuration with report, including user curve |
|||
Optional Codes |
/Optional codes |
Ordering Codes of ABB TTH300E1HBS TTH300 Head-Mount Temperature Transmitters
ABB TTH300-E1-H-BS-M5
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
We mainly supply Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.
Why do you choose us?
1. 100% original brand product, 100% quality assurance.
If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent.
2. Varied payment methods.
We adopt L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
Packaging: Imported with original packaging or standard export packing.Customize design is acceptable.
Shipping: By Express(EMS,DHL,UPS,TNT, FEDEX, ARAMEX), By Air, By Sea.
Contact:
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)