Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
General Introduction of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
Features of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
- New functions with Spectral Signal Processing (SSP) technology SSP analyses the fluid conditions inside the digitalYEWFLO vortex flowmeter and uses the data to automatically select the optimum adjustment for the application, providing features never seen before in a vortex flowmeter.
SSP accurately senses vortices in the low flow range, providing outstanding flow stability.
- Advanced self-diagnostics
Application conditions such as high pipeline vibration and abnormal flow are predicted and indicated.
- High accuracy
±0.75% of reading (liquid)
±1.0% of reading (gas, steam)
- Wide process temperature range
High temperature version up to 450 deg C
Cryogenic version minimum -196 deg C
- Simple parameter settings
Frequently-used selections grouped together in a quick-access format decrease commissioning time
- Clear, concise indicator
Convenient display of the simultaneous and total flow rates together with the process diagnosis
- Dual output for analog/pulse
Simultaneous output for flow rate and pulse
- Alarm output
An alarm signal is output when an alarm occurs.
- BRAIN/HART communication and key switches for human-machine interface
- NACE compliant
- NAMUR 43 compliant
- Remote cable length up to 30m
Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
The world's first two-wire Multi-variable Type (with built-in temperature sensor) can directly output the mass flow rate of saturated steam.
The digitalYEWFLO vortex flowmeter combines the field proven sensor and body assembly used in more than 260,000 units installed worldwide with a unique and powerful combination of digital technology that includes spectral signal processing (SSP), a Yokogawa innovation. The digitalYEWFLO vortex flowmeter is accurate and stable, even in harsh process conditions, and has a highly reliable and robust design that delivers improvements in plant efficiency and reduced operating costs.
Specification of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
|
Standard Type |
Reduced Bore Type |
Multi-Variable Type |
|
Model |
Model DY |
Option: /R1, /R2 |
Option: /MV |
|
Fluid to be Measured |
Liquid, Gas, Steam (Avoid Multiphase Flow and Sticky Fluids) |
|||
Nominal Size |
Wafer |
15 to 100 mm |
N/A |
25 to 100 mm |
Flange |
15 to 400 mm |
R1: 25 to 200 mm |
25 to 200 mm |
|
Accuracy |
Liquid |
±0.75% of Reading |
±1.0% of Reading |
±0.75% of Reading |
Gas |
±1.0% of Reading |
|||
Output Signal |
Dual Output (Both analog and pulse output available) |
|||
Process Temperature |
-29 to 250 deg C |
-29 to 250 deg C |
-29 to 250 deg C |
|
Process Pressure |
-0.1MPa (-1kg/cm2) to flange rating |
|||
Ambient Temperature |
-29 to 85 deg C (Depends on model type) |
|||
Ambient Humidity |
5 to 100% RH (No Condensation) |
|||
Mounting |
Flange or Wafer Type |
Flange Type only |
Flange or Wafer Type |
|
Electrical Connection |
JIS G1/2 Female, ANSI 1/2NPT Female, ISO M20×1.5 Female |
|||
Explosion Protected Type |
TIIS Ex d, FM Ex d/Ex ia, ATEX Ex d/Ex ia, |
|||
Material |
Body: Stainless steel(Special: Hastelloy, Carbon steel) |
Range of measurable water flow rate at standard condition Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
Model Code |
Measurable Flow Rate (m3/h) |
Range of Fixed Accuracy Flow Rate ( m3/h) |
||
DY015 |
DY025/R1 |
DY040/R2 |
0.30 to 6 |
0.94 to 6 |
DY025 |
DY040/R1 |
DY050/R2 |
0.65 to 18 |
1.7 to 18 |
DY040 |
DY050/R1 |
DY080/R2 |
1.3 to 44 |
2.6 to 44 |
DY050 |
DY080/R1 |
DY100/R2 |
2.2 to 73 |
3.3 to 73 |
DY080 |
DY100/R1 |
DY150/R2 |
4.3 to 142 |
4.6 to 142 |
DY100 |
DY150/R1 |
DY200/R2 |
7.5 to 248 |
7.5 to 248 |
DY150 |
DY200/R1 |
— |
17 to 544 |
18 to 544 |
DY200 |
— |
— |
34 to 973 |
34 to 973 |
DY250 |
— |
— |
60 to 1506 |
60 to 1506 |
DY300 |
— |
— |
86 to 2156 |
86 to 2156 |
DY400 |
— |
— |
177 to 3547 |
177 to 3547 |
Model selection and suffix codes of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
Model |
Suffix Codes |
Description |
|||||
DY015 |
Size 15 mm (1/2 inch) |
||||||
DY025 |
Size 25 mm (1 inch) |
||||||
DY040 |
Size 40 mm (1-1/2 inch) |
||||||
DY050 |
Size 50 mm (2 inch) |
||||||
DY080 |
Size 80 mm (3 inch) |
||||||
DY100 |
Size 100 mm (4 inch) |
||||||
DY150 |
Size 150 mm (6 inch) |
||||||
DY200 |
Size 200 mm (8 inch) |
||||||
DY250 |
Size 250 mm (10 inch) |
||||||
DY300 |
Size 300 mm (12 inch) |
||||||
DY400 |
Size 400 mm (16 inch) |
||||||
Output Signal and Communication |
-D |
4 to 20mA DC Output Pulse, BRAIN Communication |
|||||
-E |
4 to 20 mA DC Output Pulse, HART Communication |
||||||
-J |
4 to 20 mA DC, Pulse, HART 5/HART 7 Communication |
||||||
-F |
Digital communication, (FOUNDATION Fieldbus protocol) |
||||||
-N |
Remote type detector |
||||||
Body Material |
A |
SCS14 A |
|||||
B |
CF8M |
||||||
X |
Others |
||||||
Shedder bar Material |
L |
Duplex Stainless Steel |
|||||
B |
Stainless Steel |
||||||
E |
Duplex Stainless Steel (for TIIS Approval) |
||||||
X |
Others |
||||||
Process Connection |
AJ1 |
JIS 10 K Wafer |
|||||
AJ2 |
JIS 20 K Wafer |
||||||
AJ4 |
JIS 40 K Wafer |
||||||
AA1 |
ANSI Class 150 Wafer |
||||||
AA2 |
ANSI Class 300 Wafer |
||||||
AA4 |
ANSI Class 600 Wafer |
||||||
AD1 |
DIN PN10 Wafer |
||||||
AD2 |
DIN PN16 Wafer |
||||||
AD3 |
DIN PN25 Wafer |
||||||
AD4 |
DIN PN40 Wafer |
||||||
BJ1 |
JIS 10K Flange(RF) |
||||||
BJ2 |
JIS 20K Flange(RF) |
||||||
BJ4 |
JIS 40K Flange(RF) |
||||||
BA1 |
ANSI Class 150 Flange(RF) |
||||||
BA2 |
ANSI Class 300 Flange(RF) |
||||||
BA4 |
ANSI Class 600 Flange(RF) |
||||||
BA5 |
ANSI Class 900 Flange(RF) |
||||||
BS1 |
ANSI Class 150 Flange(RF, SF) |
||||||
BS2 |
ANSI Class 300 Flange(RF, SF) |
||||||
BS4 |
ANSI Class 600 Flange(RF, SF) |
||||||
BS5 |
ANSI Class 900 Flange(RF, SF) |
||||||
BD1 |
DIN PN10 Flange(RF) |
||||||
BD2 |
DIN PN16 Flange(RF) |
||||||
BD3 |
DIN PN25 Flange(RF) |
||||||
BD4 |
DIN PN40 Flange(RF) |
||||||
CA4 |
ANSI Class 600 Flange(RJ) |
||||||
CA5 |
ANSI Class 900 Flange(RJ) |
||||||
FD1 |
DIN PN10 Flange(R13) |
||||||
FD2 |
DIN PN16 Flange(R13) |
||||||
FD3 |
DIN PN25 Flange(R13) |
||||||
FD4 |
DIN PN40 Flange(R13) |
||||||
Electrical Connection |
-0 |
JIS G1/2 female |
|||||
-2 |
ANSI 1/2 NPT female |
||||||
-4 |
ISO M20*1.5 female |
||||||
Indicator |
D |
With Indicator |
|||||
N |
None Indicator, Remote type detector |
||||||
Optional codes |
/Optional codes |
Model selection of vortex flowmeter remote converter Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
Model |
Suffix Codes |
Description |
||
DYA |
Vortex Flowmeter Converter (Remote Type) |
|||
Output Signal and Communication |
-D |
4 to 20mA DC Output Pulse, BRAIN Communication |
||
-E |
4 to 20 mA DC Output Pulse, HART Communication |
|||
-J |
4 to 20 mA DC, Pulse, HART 5/HART 7 Communication |
|||
-F |
Digital communication, (FOUNDATION Fieldbus protocol) |
|||
Electrical Connections |
0 |
JIS G1/2 Female |
||
2 |
ASME 1/2 NPT Female |
|||
4 |
ISO M20×1.5 Female |
|||
Indicator |
D |
With Indicator |
||
N |
None Indicator |
|||
Optional codes |
/Optional codes |
Model selection of signal cable for remote transmitter Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
Model |
Suffix Codes |
Description |
||
DYC |
Signal Cable |
|||
Cable End |
-0 |
Without End finish |
||
-1 |
With End finish |
|||
Cable Length |
-## |
Designate the cable length, 5 to 95m |
||
Option |
/C# |
With termination parts sets |
Ordering Number of Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
DY Vortex Flowmeter(Integral Type, Remote type detector):
DY015-DALAA1-2D
DY025-EALAJ2-0D
DY040-EALAD4-4D
DY050-EBLBJ4-2N
DY080-JALBA5-4N
DY100-JBLBS1-4N
DY150-FALBD2-2D
DY200-EBECA4-2N
DY250-DBLAD2-4D
DY300-DBLAA2-2D
Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
DYA Vortex Flowmeter Converter(Remount type)
DYA-D2D
DYA-E2D
DYA-D0D
DYA-D0N
DYA-E0N
DYA-E0D
DYA-D4D
DYA-E4D
DYA-D4N
DYA-E4N
DYA-D2N
DYA-E2N
DYC Signal Cable:
DYC-0-05/C1/MV
Yokogawa DY200-NXBBA2-0N/HT1/SY DY200 Vortex Flowmeter DY200 Flow Meters
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
We mainly supply Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.
Why do you choose us?
1. 100% original brand product, 100% quality assurance.
If you find a fake product. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent.
2. Varied payment methods.
We adopt L/C, D/A, D/P, T/T, and other methods. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
Packaging: Imported with original packaging or standard export packing.Customize design is acceptable.
Shipping: By Express(EMS,DHL,UPS,TNT, FEDEX, ARAMEX), By Air, By Sea.
Contact:
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)